LXSG-15~50
Measurement Requirements
Temperature class; for cold water: T30, for hot water: T30/90;
Water pressure class: MAP10, MAP16 on request
Pressure-loss class: △p63
Sensitivity to the irregularity in the upstream velocity fields class; U0
Sensitivity to the irregularity in the downstream velocity fields class; D0
Maximum Permissible Error
a) In the lower zone (Q1≤Q﹤Q2)±5%
b) In the upper zone (Q2≤Q≤Q4) for water temperature up to 30°C±2% from 30°C up to 90°C±3%
Applications: to record the total volume of water passed through the pipelines.
Characteristics:
A. Magnetic coupling transmission register for its long life of clear rading.
B. Anti-magnetic field construction, excellent accuracy, and long life of service.
Note:
1. The water meter comply with the standard of << GB/T 778.1-3-2007 >> (ISO 4064-1-3:2005, IDT).
2.The following types of this series meter are available on request:
For hot water up to 90°C: LXSGR-15~50
For M type measuring insert (8 digital reading): LXSG-15M~20M, for hot water: LXSGR-15M~20M.
3. Different materials of the meter body are available on request, such as: brass and plastic.